has poor contact or an
Êîä îøèáêè |
Îïèñàíèå |
E000 |
? The thermistor (TH1, TH2) has poor contact or an open circuit ? The fixing heater (H1) has an open circuit ? The thermal switch (TSW1) has turned on ? The triac is faulty ? The DC controller PCB is faulty |
E001 |
? The thermistor (TH1, TH2) has a short circuit ? The triac is faulty ? The DC controller PCB is faulty |
E002 E003 |
The thermistor (TH1, TH2) has poor contact or an open circuit ? The fixing heater (H1) has an open circuit ? The thermal switch (TSW1) has turned on ? The triac is faulty ? The DC controller PCB is faulty |
E004 |
? The triac has a short circuit ? The DC controller PCB is faulty |
E010 |
? The main motor (M1) is faulty ? The DC controller PCB is faulty |
E013 |
? The waste toner feedscrew is locked ? The waste toner feedscrew lock sensor (PS8) is faulty ? The DC controller PCB is faulty |
E030 |
? The total copy counter has an open circuit ? The DC controller PCB is faulty |
E031 |
? The accessories counter has an open circuit ? The DC controller PCB is faulty |
(E202) |
No code indication. Keys are disabled ? The scanner home position sensor (PS1) is faulty ? The scanner motor (M2) is faulty ? The DC controller PCB is faulty |
E208 |
? The mirror home position sensor (PS3) is faulty ? The mirror motor (M4) is faulty ? The DC controller PCB is faulty |
E210 |
? The lens home position sensor (PS2) is faulty ? The lens motor (M3) is faulty ? The DC controller PCB is faulty |
E220 |
? The lamp regulator PCB is faulty ? The DC controller PCB is faulty |
E261 |
? The power supply frequency is faulty ? The power supply PCB is faulty |
E710 E711 |
? The DC controller PCB is faulty |
E712 |
? The DC controller PCB is faulty ? The ADF controller PCB is fault ? The ADF cable is faulty |
E717 |
? The DC controller PCB is faulty ? The Remote Diagnostic Device II PCB is faulty |
E800 |
? The auto power-off circuit has an open circuit ? The DC controller PCB is faulty |
E805 |
? The exhaust fan (FM2, FM4) is faulty ? The DC controller PCB is faulty |
E821 |
? The ozone filter is clogged ? The cleaner thermistor (TH3) has poor contact or an open circuit ? The DC controller PCB is faulty |